Thermal Power Plant

Thermal Power Plant
Boiler Turbine EP,ABT

Friday, June 27, 2008

CONDENSATE PUMP

CONDENSATE PUMP TAKES SUCTION FROM CONDENSER AND DELIVERS CONDENSATE WATER TO DEARATOR THROUGH MAIN EJECTORS,GLAND STEAM COOLERS AND L.P.HEATERS.CONDENSATE WATER DISCHARGED BY THE CONDENSATE PUMP IS ALSO UTILISED FOR THE SEALING OF VALVES WITH GLANDS,FOR PRDS AND DD TEMPCONTROL OF MAIN STEAM LINES AND HOT REHEAT LINES RESPECTIVELY,FOR FILLING SYPHONS OF EJECTORS AND SYPHON DRAIN EXPANDER,CONDENSATE WATER FROM INTERMEDIATE STAGE OF PUMPS IS UTILISED FOR FORCED CLOSING OF NON RETURN VALVE OF TURBINE STEAM EXTRACTION LINES AND FOR GROUP PROCTION DEVICE FOR BY PASSING OF H.P.HEATERS AND FOR COOLING DOWN THE STEAM DUMPED IN STEAM THROW OFF DEVICE BUILT IN BOTH CONDENSER.